single phase power meter ac

Single Phase Power Meter

JBH single-phase power meter shows you voltage (v), current (A), instantaneous power (kw), energy consumption (kwh), frequency (Hz) and cosine phi depending on the selected model, very nicely and accurately .

This power meter is offered in two models called AC power meter and DC power meter with two current ranges of 20 amps and 100 amps. JBH single-phase power meter comes with a 3-year unconditional warranty.

10,500,000 $

عضویت در خبرنامه JBH

JBH color single phase power meter

This single-phase AC power meter, in addition to displaying the parameters of voltage, current, power consumption, power factor (cosine phi), temperature, operating hours and energy consumption with very high accuracy, is also able to store energy consumption in the form of KWh. In the event of a power outage, the energy consumed in KWh is stored and not deleted. In addition to single-phase power meters, JBH also offers three-phase power meters.

 

AC display type single phase power meter

In addition to displaying the parameters of voltage, current, power consumption and energy consumption with very high accuracy, the single-phase power meter with AC display is able to store energy consumption in KWh. In case of power failure, the consumed energy (KWh) is stored and will not be reset. In addition, the user is able to define the upper power limit so that if the device consumes more than the set value, the device will indicate an error by flashing the backlight.

Technical specifications of AC display type single phase power meter

  • Voltage measurement range: 260-80 volts
  • Voltage display format: 260-80 volts
  • Current measurement range: type 20 (0 to 20 amps without CT) / type 100 (0 to 100 amps with CT)
  • Stream display format: 0-99.99
  • Power measurement range: 0-22 kW
  • The range of energy consumption measurement and storage: 0-9999 kilowatt hours
  • Measurement accuracy: class 1
  • Dimensions of the front frame: length 89.6 mm, width 49.6 mm
  • Dimensions of the rear frame: length 84.6 mm, width 44.6 mm
  • Depth: 24.4 mm

تصویر کنتور دیجیتال تک فاز

Application of single-phase AC display type power meter

  • Home fuse box: as a digital meter for constant monitoring of voltage, current, instantaneous power and energy consumption, or so to speak, the same kilowatt hours consumed by residential, commercial and office units.
    Distribution board of residential and commercial complexes: In many commercial, residential and administrative centers where the units do not have independent electricity branches, one of the challenges is to calculate the electricity consumption of each unit. In fact, this product plays the role of a resettable digital meter with the utmost precision.
    Single-phase switchboard: as a digital meter for constant monitoring of voltage, current, instantaneous power and energy consumption, or the same as the kilowatt-hour consumption of the switchboard.
    Industrial equipment and machinery: as a meter for constant monitoring of voltage, current, instantaneous power and energy consumption or so called the same kilowatt hour consumption of that equipment
    Miner Farms: as a meter for constant monitoring of voltage, current, instantaneous power and energy consumption, or in other words, the same kilowatt hours consumed by each miner or any group of miners that have different owners.

100 amp type

In this type, the 2 upper pins are related to the current transformer or CT connection, and the lower 2 pins are related to powering the power meter itself. Additionally, run that phase wire that feeds your consumers through the current transformer.

نصب و راه اندازی پاورمیتر تک فاز

20 amp type

In this type, there is no current transformer. The 2 upper legs are related to the direct connection of the consumer and the lower two legs are related to the power meter itself.

وایرینگ پاورمیتر تک فاز

How to apply single phase AC display type power meter settings

  • Turn the backlight on or off
    Press the settings button momentarily.
    High power limit setting
    Hold the setting button for 5 seconds until SET CLR appears. Release the button as soon as the relevant phrase appears. When the three-digit power number flashes, hold the button and increase the first digit until it reaches your desired value, then release the button and wait for the second digit to flash. After the second digit flashes, set the second digit according to the previous procedure. The third digit can be adjusted in the same way. After setting all the numbers, hold the button for 5 seconds to save the settings until the first screen appears.
    Reset the amount of energy consumed (KWh)
    Hold the setting button for 5 seconds until SET CLR appears. Do not release the button. Release the button when the number corresponding to the energy consumption appears and the light of the device is flashing. Perform the reset operation with a momentary press, and if you skip the reset, hold the button for 5 seconds to return to the first window.تصویر کنتور دیجیتال تک فاز مدباس

Single phase power meter, Modbus AC type

Modbus AC single-phase power meter provides voltage, current, frequency, cosine phi, power consumption and energy consumption parameters with high accuracy in RS485 platform under MODBUS RTU protocol. In addition, this product is able to store energy consumption in the form of KWh. In case of power failure, the consumed energy (KWh) is stored and will not be reset. It is worth mentioning that the user is able to define the address of the modbus, reset the kilowatt hours and set the upper power limit so that if the power consumption exceeds the set amount, the device will automatically send an alarm bit.

Technical specifications of single-phase power meter, Modbus AC type

  1. Voltage

  • Voltage measurement range: 260-80 volts
  • Voltage display format: 260.0 – 80.0 V
  • Voltage measurement accuracy: 0.5%

  1. current

  • Current measurement range: type 10 (0 to 10 amps without CT) / type 100 (0 to 100 amps with CT)
  • Stream display format: 0 – 99.999
  • Current measurement accuracy: 0.5%

  1. active power

  • Active power measurement range: Type 10 (0 to 2.3 kW) / Type 100 (0 to 23 kW)
  • Resolution: 0.1 W

  1. Energy consumption

  • Range of measurement and storage of consumed energy: 9999.99 – 0 kilowatt hours
  • Measurement accuracy: 0.5%
  • Resolution: 1 watt hour

  1. Frequency

  • Frequency measurement range: 45-65 Hz
  • Measurement accuracy: 0.5%
  • Resolution: 0.1 Hz

  1. cosine phi

  • Measurement range: 0-1
  • Measurement accuracy: 1%
  • Resolution: 0.01
  • Dimensions of the front frame: length 90 mm, width 60 mm
  • Dimensions of the rear frame: length 90 mm, width 60 mm
  • Depth: 28 mm

 

DC display type single phase power meter

In addition to displaying parameters of voltage, current, power consumption and energy consumption (KWh) with high accuracy, the DC power meter is able to store energy consumption in the form of KWh. In case of power failure, the consumed energy (KWh) is stored and will not be reset. In addition, the user is able to define the upper and lower limits of the voltage so that if it increases or decreases more than the set value, the device will indicate an error by flashing the backlight.

 

Technical specifications of DC display type single phase power meter

  • Voltage measurement range: 6.5-100V
  • Voltage display format: 6.5-99.9V
  • Current measurement range: type 20 (0 to 20 amps without shunt) / type 100 (0 to 100 amps with shunt)
  • Current display format: type 100 (0-99.99 amps) / type 20 (20.00-00.00 amps)
  • Power measurement range: Type 100 (0-10 KW) Type 20 (0-2 KW)
  • Range of measurement and storage of consumed energy: 0 – 9999 KWh
  • Measurement accuracy: class 1
  • Dimensions of the front frame: length 89.6 mm, width 49.6 mm
  • Dimensions of the rear frame: length 84.6 mm, width 44.6 mm
  • Depth: 24.4 mm

 

How to apply the settings of single-phase DC display type power meter

1. Turn on or off the backlight

Press the settings button momentarily.

 

2. Adjusting the high and low voltage limits

Hold the setting button for 3 seconds until SET appears. Release the button as soon as the relevant phrase appears. When the three-digit number corresponding to the upper limit flashes, each time you press the button, increase the first digit by one unit to reach your desired value. Then release the button and wait for the second digit to flash. After the second digit flashes, set the second digit according to the previous procedure. The third digit can be adjusted in the same way. After setting all the numbers, wait for the number on the right, which is the lower voltage limit, to blink. Set the lower voltage limit according to the mentioned procedure. To save the settings, hold the button for 5 seconds until the first screen window appears after the word pass is displayed.

3. Resting the amount of energy consumed (KWh)

Hold the settings button for 5 seconds until the word CLR appears. Release the button. When the number related to the consumed energy appears and the light flashes, perform the reset operation with a momentary push and if you skip the reset, hold the button for 5 seconds to return to the first window.

4. Setting the current ranges of 50 and 100 amperes

This setting is for 100 amp type. If you connect a 50 amp shunt, set these settings to 50 A, and if you connect a 100 A shunt, set these settings to 100 A. The way to set it is to hold the button for 7 seconds until the word CURR appears. Then you can set your favorite amp by pressing the button once. Then hold the button for a few seconds until the value is saved and the first screen appears.

5. Setting the single-phase power meter in the fuse box

In case of power failure, the consumed energy (KWh) is stored and will not be reset. It is worth mentioning that the user is able to define the address of the modbus, reset the kilowatt hours and set the upper power limit so that if the power consumption exceeds the set amount, the device will automatically send an alarm bit. The small dimensions and very high accuracy of this product have attracted the attention of the activists in the field of industrial automation.

 

Technical specifications of Modbus AC single-phase power meter
Voltage

Voltage measurement range: 260-80 volts

Voltage display format: 260.0-80.0 volts

Voltage measurement accuracy: 0.5%

 

current

Current measurement range: type 10 (0 to 10 amps without CT) / type 100 (0 to 100 amps with CT)

Stream display format: 0 – 99.999

Current measurement accuracy: 0.5%

 

active power

Active power measurement range: Type 10 (0 to 2.3 kW) / Type 100 (0 to 23 kW)

Resolution: 0.1 W

 

Energy consumption

Range of measurement and storage of consumed energy: 9999.99 – 0 kilowatt hours

Measurement accuracy: 0.5%

Resolution: 1 watt hour

 

Frequency

Frequency measurement range: 45-65 Hz

Measurement accuracy: 0.5%

Resolution: 0.1 Hz

 

cosine phi

Measurement range: 0-1

Measurement accuracy: 1%

Resolution: 0.01

Dimensions of the front frame: length 90 mm, width 60 mm

Dimensions of the rear frame: length 90 mm, width 60 mm

Depth: 28 mm

محصولات جی بی اچ
barcode

color ac – 11206, ac Madbas – 11202

Quantity in box

1

number in the box

10

Technical code of the single-phase ac colored power meter product

KWS-AC300-100A

Technical code of Madabas single-phase ac power meter product

JRMP-1P-100-485

Reviews

There are no reviews yet.

Be the first to review “single phase power meter ac”

Your email address will not be published. Required fields are marked *

Reviews

There are no reviews yet.

Be the first to review “single phase power meter ac”

Your email address will not be published. Required fields are marked *

technical support
Scroll to Top