How the fixed three-phase voltage protector works

How the three-phase fix voltage protector works in jbh, if the measured values ​​of voltage and current exceed the set range, the device cuts off the output power according to the set time and reconnects the output power after the set time if the error is fixed. .

Applications of fixed three-phase voltage protection

1- Home use: inside the fuse box of houses for three-phase electricity
2- All kinds of industrial devices and three-phase uses, such as motors, pumps, miners, etc.
3-Installation in all kinds of industrial switchboards in three-phase branches

 

Product specification table

parameters current suffering Product Code Product Name Shape
over voltage: 440±5V
Under Voltage: 330±5V
action time: 0.3 Sec
Recovery time: 60 Sec
 

63A

 

P24063F0

VP-3F

Voltage Protector Fix type

تصاویر-محصولات-سایت7-0114-300x196

Technical specification table

 

1 Voltage supply: 230…400 Vac
2 operating temperature: -30 … 70 Celsius
3 frequency : 50Hz/60Hz
4 Power Consumption : < 2W
5 electrical life: 100.000 times
6 Mechanical life: 1.000.000 times
7 surge protection capacity: 175 Joules
8 Max current / Spike voltage: 6000A/1.5KV
9 voltage measuring accuracy : <1%
10 rated insulation voltage: 600 Vac
11 protection deegre: IP40 for front panel & IP20 for terminals
12 pollution degree: 3
13 operation position :any
14 over voltage category: III
15 Install way: DIN-rail mounting
16 Efficiency : 97%
17 Warranty : 3 years
18 Altitude above sea: no more than 2000 m
19 humidity : <90%
20 category : AC7-a
21 action time: <300ms

 

Fix three-phase voltage protector installation tips

1- It is recommended to use an expert for installation and settings
2- It is recommended to use an original miniature fuse and a current leakage protector before the protector.
3- According to the figure above, the input phases should be connected to L1, L2, and L3, and the input neutral should be connected to N, and in the same way, the output neutral should be connected to the null ingot and the output phases should be connected to the input of the miniature fuses.
4- To connect the wire to the device, be sure to use the appropriate wire head
5- Make sure the connections are tight because loose connections cause heat and fire.

The dimensions of the fixed three-phase voltage protector

تصویر ابعاد محافظ ولتاژ سه فاز فیکس

Cut diagram

تصویر نمودار قطع محافظ ولتاژ سه فاز فیکس

Reviews

There are no reviews yet.

Be the first to review “Fixed three-phase voltage protector”

Your email address will not be published. Required fields are marked *

Reviews

There are no reviews yet.

Be the first to review “Fixed three-phase voltage protector”

Your email address will not be published. Required fields are marked *

technical support
Scroll to Top