power meter dc

DC Power Meter 

In addition to displaying the parameters of voltage, current, power consumption and energy consumption with very high accuracy, the DC display power meter is able to store the energy consumption in the form of KWh. This product comes with a 3-year warranty.

This power meter is stored and not reset in case of power failure. In addition, the user is able to define the upper and lower limits of the voltage so that if it increases or decreases more than the set value, the device will notify by flashing the background light. make a mistake

11,200,000 $

Availability: 5 in stock

عضویت در خبرنامه JBH

Technical specifications of DC power meter

In general, there are different types of power meters that differ from each other in terms of technical specifications. Modbus, single-phase and DC power meters are types of power meters that we discuss in this section about DC power meters.

  • Voltage measurement range: 6.5-100V
  • Voltage display format: 6.5-99.9V
  • Current measurement range: type 20 (0 to 20 amps without shunt) / type 100 (0 to 100 amps with shunt)
  • Current display format: type 100 (0-99.99 amps) / type 20 (20.00-00.00 amps)
  • Power measurement range: Type 100 (0-10 KW) Type 20 (0-2 KW)
  • Range of measurement and storage of consumed energy: 0 – 9999 KWh
  • Range of measurement and storage of consumed energy: 0 – 9999 KWh
  • Dimensions of the front frame: length 89.6 mm, width 49.6 mm
  • Dimensions of the rear frame: length 84.6 mm, width 44.6 mm
  • Depth: 24.4 mm

 

How to apply settings in DC power meter

Almost the way DC power meter works is the same as single-phase power meter, but there are minor differences from each other. In the following, we discuss how this power meter works.

  • Turn the backlight on or off

Press the settings button momentarily.

  • High and low voltage limit setting

Hold the setting button for 3 seconds until SET appears. Release the button as soon as the relevant phrase appears. When the three-digit number corresponding to the upper limit flashes, each time you press the button, increase the first digit by one unit to reach your desired value. Then release the button and wait for the second digit to flash. After the second digit flashes, set the second digit according to the previous procedure. The third digit can be adjusted in the same way. After setting all the numbers, wait for the number on the right, which is the lower voltage limit, to blink. Set the lower voltage limit according to the mentioned procedure. To save the settings, hold the button for 5 seconds until the first screen window appears after the word pass is displayed.

  • Reset the amount of energy consumed (KWh)

Hold the settings button for 5 seconds until the word CLR appears. Release the button. When the number related to the consumed energy appears and is flashing, perform the reset operation with a momentary press, and if you skip the reset, hold the button for 5 seconds to return to the first window.

  • Setting the current ranges of 50 and 100 amperes

This setting is for 100 amp type. If you connect a 50 amp shunt, set these settings to 50 A, and if you connect a 100 A shunt, set these settings to 100 A. The way to set it is to hold the button for 7 seconds until the word CURR appears. Then set to the desired value by pressing the button once. Then hold the button for a few seconds until the value is saved and the first screen appears.

Order code

11201

Quantity in box

1

number in the box

10

Reviews

There are no reviews yet.

Be the first to review “power meter dc”

Your email address will not be published. Required fields are marked *

Reviews

There are no reviews yet.

Be the first to review “power meter dc”

Your email address will not be published. Required fields are marked *

technical support
Scroll to Top