JBH single phase power meter

پاورمیتر تک فاز JBH

JBH single phase power meter

 

JBH single phase power meter

JBH single phase power meter, voltage (v), current (A), instantaneous power (kw), energy consumption (kwh), frequency (Hz) and cosine Phi depending on the selected model, very beautiful and with the desired accuracy Gives .

This power meter is offered in two models, AC and DC, with two current ranges of 20 amps and 100 amps.

کنتور دیجیتال تک فاز

JBH single phase power meter

JBH single phase power meter type AC display

AC phase single phase power meter, in addition to displaying the parameters of voltage, current, power consumption and energy consumption with very high accuracy, is able to store energy consumption in KWh. In case of power failure, energy consumption (KWh) is stored and will not be reset. On this, the user is able to define the upper limit of power so that if the device consumes more than the set value, the device will announce an error by flashing backlight.

مشخصات فنی پاورمیتر تک فاز jbh

Technical specifications of JBH single phase power meter, AC display type

Voltage measurement range: 260-80 volts

Voltage display format: 260-80 volts

Current measurement range: Type 20 (0 to 20 amps without CT) / Type 100 (0 to 100 amps with CT)

Stream display format: 99.99-0

Power measurement range: 0 – 22 kW

Measurement and storage range of energy consumption: 09999 – 0 kWh

Measurement accuracy: Class 1

Dimensions of the front frame: length 89.6 mm, width 49.6 mm

Dimensions of the rear frame: length 84.6 mm, width 44.6 mm

Depth: 24.4 mm

کاربرد پاورمیتر تک فاز

Application of single phase power meter JBH type AC display

  • Household fuse box: As a digital meter for constant monitoring of voltage, current, instantaneous power and energy consumption or the so-called kilowatt-hour consumption of residential, commercial and office units
  • Distribution board of residential and commercial complexes: In many commercial, residential and office centers where the units do not have independent power outlets, one of the challenges is to calculate the electricity consumption of each unit. In fact, this product plays the role of a resetable digital meter for you as accurately as possible.
  • Single-phase switchboard: as a digital meter for constant monitoring of voltage, current, instantaneous power and energy consumption or the so-called kilowatt-hour switchboard
  • Industrial equipment and machinery:  Equipped as a meter for constant monitoring of voltage, current, instantaneous power and energy consumption or the so-called kilowatt-hour of consumption
  • Miner farms: as a meter for constant monitoring of voltage, current, instantaneous power and energy consumption, or the so-called kilowatt-hours consumed by each miner or any group of miners that have different owners.

 

نحوه نصب و راه اندازی چراغ سیگنال ولتمتر jbh

Type 100 amps

In this type, the top 2 pins are related to the junction of the current transformer or CT. And the bottom two pins are related to the power supply of the power meter itself. In addition, run the fuzzy wire that feeds your consumers that you want to measure the current through the current transformer. Yes, just that.

 

 

نصب و راه اندازی پاورمیتر تک فاز

 

Type 20 amps

In this type, there is no current transformer. The top 2 pins are for the direct connection of the consumer and the bottom two pins are for the power meter itself.

وایرینگ پاورمیتر تک فاز

 

 

  • How to apply JBH single phase AC meter power meter settings
  • Turn the backlight on or off

Press the settings button momentarily.

  • Adjust the power limit

Hold down the Settings button for 5 seconds until the SET CLR phrase appears. Release the button as soon as the corresponding phrase appears. When the three-digit number for power flashes, hold down the button to increase the first digit to your desired value. Then release the button and wait for the second digit to flash. After the second digit flashes, adjust the second digit according to the previous procedure. The third digit can be adjusted in the same way. After setting all the digits, hold down the button for 5 seconds to save the settings until the first window of the screen appears.

  • Reset the amount of energy consumed (KWh)

Hold down the Settings button for 5 seconds until SET CLR appears. Do not release the button. Release the button when the power consumption number appears and flashes. Perform a reset operation with a momentary push, and if you do not reset, hold the button for 5 seconds to return to the first window.

کنتور دیجیتال تک فاز مدباس

JBH Adapted Single Phase Power Meter

Single phase power meter JBH Adbas type AC

The AC Modbas single-phase power meter provides voltage, current, frequency, cosine, power and energy parameters with very high accuracy in the RS485 substrate under the MODBUS RTU protocol. In addition, this product is able to store energy consumption in KWh. In case of power outage, energy consumption (KWh) is saved and will not be reset. If more than the set power is consumed, the device will automatically send an alarm bit.

Technical specifications of JBH single phase AC power meter

Voltage

Voltage measurement range: 260-80 volts

Voltage display format: 260.0 – 80.0 volts

Voltage measurement accuracy: 0.5%

current

Current measurement range: Type 10 (0 to 10 amps without CT) / Type 100 (0 to 100 amps with CT)

Stream display format: 99.999-0

Flow measurement accuracy: 0.5%

Active power

Active power measurement range: Type 10 (0 to 2.3 kW) / Type 100 (0 to 23 kW)

Resolution: 0.1 watt

Energy consumption

Energy consumption measurement and storage range: 09999.99 – 0 kWh

Measurement accuracy: 0.5%

Resolution: 1 watt hour

Frequency

Frequency measurement range: 65-45 Hz

Measurement accuracy: 0.5%

Resolution: 0.1 Hz

cosine fi

Measurement range: 1-0

Measurement accuracy: 1%

Resolution: 0.01

Dimensions of the front frame: length 90 mm, width 60 mm

Dimensions of the rear frame: length 90 mm, width 60 mm

Depth: 28 mm

The table of Madbas addresses is provided in the catalog along with the product.

کنتور dc

Power meter dc

JBH single phase power meter type DC display

In addition to displaying the parameters of voltage, current, power consumption and energy consumption (KWh) with very high accuracy, DC power meter is able to store energy consumption in KWh. In case of power failure, energy consumption (KWh) is stored and will not be reset. On this, the user is able to define the upper and lower limits, the voltage, so that if the device increases or decreases more than the set value, the device will announce an error by flashing the backlight.

Technical specifications of JBH single phase power meter DC display type

Voltage measurement range: 100 – 6.5 volts

Voltage display format: 99.9-6.5V

Current measurement range: Type 20 (0 to 20 amps without shunt) / Type 100 (0 to 100 amps with shunt)

Current display format: Type 100 (99.99 – 0 amps) / Type 20 (20.00-00.00 amps)

Power measurement range: Type 100 (0-10 KW) Type 20 (0-0 KW)

Measurement and storage range of energy consumption: 09999 – 0 KWh

Measurement accuracy: Class 1

Dimensions of the front frame: length 89.6 mm, width 49.6 mm

Dimensions of the rear frame: length 84.6 mm, width 44.6 mm

Depth: 24.4 mm

How to apply JBH single phase DC meter type DC display settings

  • Turn the backlight on or off

Press the settings button momentarily.

  • Adjust the upper and lower voltage limits

Hold the Settings button for 3 seconds until the SET phrase appears. Release the button as soon as the corresponding phrase appears. When the three-digit number corresponding to the upper limit flashes, each time you press the button, increase the first digit by one to reach the desired value. Then release the button and wait for the second digit to flash. After the second digit flashes, adjust the second digit according to the previous procedure. The third digit can be adjusted in the same way. After adjusting all the digits, wait for the number on the right, which is the lower limit of the voltage, to flash. Adjust the lower voltage limit according to the procedure. To save the settings, hold down the button for 5 seconds until the first window of the display appears after the pass phrase is displayed.

  • Reset the amount of energy consumed (KWh)

Hold down the Settings button for 5 seconds until CLR appears. Release the button. When the power consumption number appears and flashes, perform a reset operation with a momentary pressure, and if you do not reset, hold the button for 5 seconds to return to the first window.

  • Adjust current ranges of 50 and 100 amps

These settings are for the 100 amp type. If you connect a 50 amp shunt, set these settings to 50 A and if you connect a 100 A shunt, set these settings to 100 A. The setting is to hold the button for 7 seconds until the CURR statement appears. Then set the desired value by pressing the button once. Then hold down the button for a few seconds until the saved value appears and the first screen appears.

 

محصولات جی بی اچ

Jbh products

× How can I help you?