Temperature and humidity controllers

Project Description

 

JBH temperature and humidity controller

Introduction

The temperature and humidity controller, in addition to displaying the values ​​of temperature and humidity, performs temperature control in two modes of cooling and heating and humidity control in two modes of humidifier and dehumidifier.

Technical Specifications

Temperature measurement range: +110 … -50 ° C

Humidity measurement range: 100% …. 0

Resolution: 0.1

Measurement accuracy: 1%

Power supply: 220 Vac

Output relay current: 220 Vac 10A

 

How to apply the settings

Set the temperature point set to disconnect and connect the relay

Buttons number 1 are related to setting the start time and temperature relay step. The ˄ button is for setting the starter temperature or connecting the relay and the ˅ button is for setting the step temperature or disconnecting the temperature relay. Each time you press these buttons, the values ​​set by the user are displayed. Now to change the button settings Hold the starter temperature setting for a few seconds until the seven temperature-related segments flash. After the number flashes, set the starter temperature to the desired temperature with the number 1 buttons. After setting the starter temperature, wait a few moments for the device to automatically save the changes. Do the same process to adjust the step temperature.

Setting the humidity point set to disconnect and connect the humidity relay

Buttons number 2 are related to setting the start time and step of the humidity relay. The ˄ button is for setting the humidity of the starter or the same as connecting the relay and the button است is for setting the humidity of the step or disconnecting the humidity relay. Hold down the starter humidity adjustment button for a few seconds until the seven humidity segment flashes. After the number flashes, adjust the starter humidity to the desired humidity with the number 2 buttons. After setting the starter humidity, wait a few moments for the device to automatically save the changes. Do the same process to adjust the step moisture.

Calibrate temperature and humidity values

Press the number 1 buttons at the same time until the temperature number flashes. After flashing, calibrate the temperature with the same keys. Press the number 2 buttons at the same time until the humidity number flashes. After flashing, calibrate the humidity with the same keys.

Introduction

In addition to displaying the temperature and temperature regulation, the JBH micro thermostat is able to control the temperature in both cooling and heating operating modes based on the user’s adjustable temperature.

Technical Specifications

Flow measurement range: +110 … -50 ° C

Resolution: 0.1 ° C for range (99.9+ … 9.9-) and 1 ° for outside range

Measurement accuracy: 0.1 ° C

Control accuracy: 0.1 ° C

Reading cycle: 0.5 seconds

Power supply: 12 VDC 200 mA

Measuring sensor: NTC 10 K waterproof

Output relay current: 10 amps

Working temperature of the device: 60+ … 10- degrees Celsius

Working humidity: 85% … 20%

Dimensions of the front frame: length 48 mm, width 29 mm, depth 32 mm

Rear frame size: length 46 mm width 26.5 mm

How to apply the settings

Adjust the disconnect and reconnect temperature of the value by pressing and releasing the SET button once. The low number, which is the user’s set temperature and is indicated by the seven blue segments, flashes. Then the value of this parameter can be increased and decreased with both buttons. Use the ‘C /’ F button to switch between Celsius and Fahrenheit. This thermostat has 9 functions P0 to P9. Hold down the SET key for a few seconds until P0 appears. Release the key and then move between functions each time you press the SET key. To set each of these 9 functions, hold down both buttons simultaneously until the numeric value of the corresponding parameter flashes. Then increase and decrease the numeric value of the parameter with the up and down buttons.

Introduction of functions

P0: C (cooling) H (heating)

P1: Adjusts the hysteresis temperature value

P2: Limit the set point by setting the maximum set point

P3: Limit the set point by setting the minimum set point

P4: Calibrate the current temperature

P5: Set the delay time in connecting the relay if the current set point and temperature are equal

P6: Enable or disable P2 and P3 functions

P7: Change the unit of measurement from Celsius to Fahrenheit and vice versa

P8: Enable or disable factory settings

Introduction

In addition to displaying the temperature and temperature regulation, the JBH macro thermostat is able to control the temperature in both cooling and heating operating modes based on the user’s adjustable temperature. In this way, if the set temperature is set higher than the current temperature, the device automatically enters the heating mode and the heating LED lights up, and vice versa, if the set temperature is set below the current temperature, the device automatically enters the cooling mode and The cooling ID lights up.

Technical Specifications

Temperature measurement range: 99+ … 50- degrees Celsius

Resolution: 0.1 ° C for range (99.9+ … 9.9-) and 1 ° for outside range

Measurement accuracy: 1 ° C (from -50 to +70)

Power: VAC ± 10% 220

Measuring sensor: NTC 10 K waterproof with a length of 1 meter

Output relay: Cooling relay (10A / 250VAC (10A / 250VAC)

Operating temperature of the device: 60+ … 0 degrees Celsius

Working humidity: 85% … 20%

Dimensions of the front frame: length 75 mm, width 34.5 mm

Rear frame size: length 71 mm width 29 mm

      Default               Setting range
                                                    Function       Code
            10 50- to +99 degrees Celsius Set the optimum temperature for cooling or heating           F1  
             3 1 to 10 degrees Celsius Adjust the differential value           F2          
             3 1 to 10 minutes Set the delay time in connecting the compressor           F3        
             0 10- to +10 degrees Celsius Adjust the calibration value           F4        

 

Introduction
In addition to displaying the temperature and regulating the temperature, the JBH eco-thermostat is able to control the temperature in two cooling operating modes.
And heating is based on the user’s set temperature.

Technical Specifications
Temperature measurement range: 120 … + 50 degrees Celsius –
Measurement accuracy: 0.1 ° C
Power supply: VAC 220
Measuring sensor: NTC 10 K waterproof
Output relay current: 10 amps
Operating temperature of the device: 60 … + 10 degrees Celsius –
Working humidity: 85% … 20
Dimensions of the front frame: length 78 mm, width 40 mm, depth 24 mm
Rear frame size: length 69 mm width 37 mm

How to apply the settings
Set the setpoint temperature for disconnecting and connecting the relay by pressing the SET button for 3 seconds and
Let go. The low number is the same as the user’s set temperature, which is marked with a blue color
Becomes. Then with both up and down buttons, the value of this parameter can be increased and decreased. This thermostat
It has 9 functions P0 to P8. Hold down the SET key for 10 seconds until P0 appears. Release the key
And then move between functions each time you press the SET key. To quantify any of these
9 Functions Increase and decrease the numeric value of the parameter with the up and down buttons. To store prescriptions
Hold down the SET key for a few seconds.

Introduction of functions
P0: Cooling (H) Heating (C)
P1: Adjust the value of the differential temperature) for example if you set the Pointe set number 25 degrees in heating mode and
You have set the differential temperature to 2 degrees and the ambient temperature is 20 degrees, the relay is connected to increase the temperature.
2 + 25. After reaching the temperature of 27, the relay is disconnected and in case of disgust, the temperature drops below 25 degrees,
This cycle is repeated. In general, the eco-thermostat constantly maintains a temperature between 25 and 27.
P2: Limit the set point by setting the maximum set point
P3: Limit the set point by setting the minimum set point
P4: Calibrate the current temperature

P5: Set the delay time in connecting the relay if the set point and current temperature are equal (for the compressor,
Refrigerator and … (
P6: Set the current temperature limit display to on and off
P7: Lock setpoint settings
P8: Factory settings) Set the P8 parameter to ON and do not press any buttons for a few seconds.